Direct Burial Loop Installation Guide

A quick-reference guide for direct burial loops used with vehicle detection systems.

Concrete: keep the loop above the rebar

  • Position the loop above the rebar.
  • Use straps as needed to maintain the loop’s shape.
  • Aim for at least 3 inches of clearance between the loop and the finished concrete surface.
  • Connect the loop to a detector and adjust the detector’s sensitivity to address interference between the loop and rebar.

Asphalt: protect the loop from heat

  • Do not allow hot asphalt to contact the loop. Hot asphalt will damage it.
  • Place the loop in the crusher run stone or sand layers, creating a buffer between the loop and the hot asphalt.
  • Connect the loop to a loop detector.

Gravel: bury deeper and protect against sharp stones

  • For an existing gravel road or driveway, create a trench for the loop.
  • Bury the loop at least 6 inches below the surface to help protect it as the gravel wears down.
  • Cover the loop with sand or fine-grain stone.
  • Avoid direct contact with sharp or large gravel stones to help extend the loop’s life.
  • Connect the loop to a detector.

Before you install

Choose the installation method for your surface and plan the required depth and protective material before placing the loop. Important installation notice: Test for continuity before installing